O2k-Startup

The experimental system complete for basic high-resolution respirometry (HRR).

Product ID: 10203-03

The O2k Startup enables the following O2k-Applications:

  • oxygen consumption

The O2k Startup does not include, but fully supports O2k-Fluorometry and the O2k−Modules: O2k-PB-Module, O2k-TIP2k-Module, O2k-TPP+ ISE-Module, O2k-pH ISE-Module.

This package is available as a Power Package to increase throughput. Certain auxiliary tools and services are not included in Power Packages.
This package is also available without integrated PC. Certain items are not included in O2k-Packages without an integrated PC.

More details:
Compare packages

For O2k-J and higher, please use DatLab 8 to ensure proper operation and data acquisition for all O2k-Modules.

 

Award-winning innovation

Additional information

Oxygen

Respiration chambers with minimum oxygen diffusion
• High-resolution of oxygen flux: ±1 pmol O₂ ∙s⁻¹∙mL⁻¹ in normoxia to anoxia
• High-resolution of oxygen concentration: 5 nM
• Long-term stability and linearity of the polarographic oxygen sensor (OroboPOS)
• Barometric pressure transducer for accurate air calibration at any altitude

SUIT protocols

Standardized substrate-uncoupler-inhibitor-titration DL-Protocols
• Real-time monitoring of respiratory rates and states
• Multiple titrations within a single assay for in-depth analysis of mitochondrial fitness

MultiSensor

Additional parameters recorded real-time in combination with oxygen in the same chamber
• Automatic and documented calibration routines, instrumental background tests, and mitochondrial assays supported by DL-Protocols

Temperature

4 to 47 °C; stability ±0.002 °C

Thermostat

Peltier temperature control

Chamber

Material: Duran glass
Volume: 2 mL or 0.5 mL

Specialized DatLab Software

Installed on integrated computer for protocol design, control and data analysis

Max. power input

330 W

Current at 100-120 V

max. 3.0 A

Current at 220-240 V

max. 1.5 A

Power consumption

During standard operation with screen (when block temperature is stable at 37 °C and ambient temperature of 22 °C) approx. 45-50 W

Lab space required

The O2k requires a minimum of lab space (0.5 m bench space), with sufficient space for the ISS, Titration Set and handling.
For maximum signal stability and optimal temperature control, the O2k should be placed in a position in which it is not exposed to direct sunlight and sudden changes of room temperature. Keep the space on the table below the O2k bottom clear to prevent any interference of ventilation beneath the O2k-Main Unit.

Configuration

O2k: Hardware and DatLab Software*

Stainless steel housing
Peltier thermostat 4 to 47 °C; ±0.002 °C
Barometric pressure transducer
2 Amperometric oxygen channels
2 ISE sockets for ion sensitive electrodes
2 Sockets for optical signals
2 Sockets for PB-Module
2 O2k-Chambers (2.0 mL, Duran® glass)
2 SmartPOS
2 stirrers (white PVDF) , electromagnetic control
2 stoppers (black PEEK) with O-ring
2 O2k-Chamber Holders (blue POM) with O-ring and V-ring
2 POS-Holders (blue POM)

Current DatLab version with free follow-up upgrades within the warranty period

O2k: Accessories and Consumables                                                                                                  

1 ISS-Integrated Suction System, to remove medium from the O2k-Chamber
1 O2k-Titration Set: Hamilton microsyringes; fixed needles with rounded tips (8 x 10 mm3 and 3 spare plungers, 6 x 25 mm3, 2 x 50 mm3, 1 x 100 mm3, 1 x 500 mm3), packed in syringe storage box with syringe labels, 2 x syringe racks with syringe collars, 2 x tube racks
1 MiR05-Kit: Mitochondrial Respiration Medium. For a final volume of 250 mL
1 Pkg. POS-Seal Tip
2 Pkg. POS-Membranes
1 POS-Electrolyte Powder
1 POS-Mounting Tool
1 Polishing Cloth
1 Polishing Powder 0.3 μm
1 O2-Zero Powder
1 Forceps for membrane application
1 Pipette Plastic ungraded
1 Pkg. Conditioning cloths for stainless-steel housing

O2k-sV-Module: small chamber volume to reduce the sample amount needed for OXPHOS analysis and cellular/mitochondrial respiratory function

2 O2k-Chambers-sV (Duran® glass), with smaller operation volume (V) of 0.5 mL
2 stirrers sV (white PVDF) for small volume chambers, electromagnetic control
2 stoppers sV (black PEEK) for small volume chambers with O-ring
2 O2k-Chamber Holders sV (black POM) with O-ring and V-ring
2 POS-Holders sV (black POM)

Included extras                                                                                           

Packing, handling, worldwide shipping
Remote support from Oroboros experts
1 Installation and startup support session (remote, to be used within the warranty period)
1 O2k-Workshop registration fee for the participation of one lab member waived (to be used within the warranty period)
3-year warranty
* Integrated computer with touch screen (15,6″; FHD 1920×1080) connects DatLab to the O2k
* Keyboard set, webcam and webcam accessories

 

All trademarks used are properties of their respective owners.

Bioblast resources

Visit Bioblast where you will find further relevant information:

• O2k manual

Subscribe to O2k-Communications